First Delivery for Field Trial

VSI delivered the first Helical Bevel Gear-drive Valve, the HBGV, on Thursday, February 18, 2016. The valve will be installed as a pump back pressure regulator on an injection skid manufactured by Global Production Systems, GPS, in Shawnee, Ok.

DSCF2833

 

GPS is a leader in injection systems design and manufacturing that include instrumentation and control systems permitting the multi-stage centrifugal pumps to operate most efficiently.

While this marked a significant milestone for VSI in the development of the HBGV, the near future looks bright as we actively seek other field trial applications for a 5,000 psi rated choked flow control valve with a flow coefficient up to 60.

We have two API 6A compliant valves and one Class 1500 RF flanged valve in production, ready soon to drop in and replace problem-plagued 2″ conventional control valves. The electronic actuation system is capable of 1% accuracy with 20:1 rangeability. HBGV SN160201 Assembled

Flow Lab Tests Complete – Performance Confirmed

IMG_20160128_111431559The final round of lab testing wrapped up this week. Flow test data gathered at the Radford Company valve test facility confirmed predictions of CFD simulations made prior to the launch of VSI. Maximum Flow Coefficient was measured to be 75 in turbulent flow. The HBGV1 was confirmed to have negligible pressure recovery in the valve and an effective CsubV of nearly 60 in full choked flow as pressure recovered far downstream.